bg sanpham
16 Channel Input/Output Board 16 Channel Input/Output Board The FireNET FN-4127-IO is a 16 channel Input/Output board that provides powerful input/output expansion & addition to the FireNET system allowing up to thirty two I/O boards to be connected to each FireNET panel within the FireNET network. Every I/O board connected to any panel is available to the entire network, which allows for network wide input/output mapping. Typical uses include graphical LED map displays/annunciators, tabular LED zone display/ annunciators, input/output logic to & from the fire system for secondary use (I/O board points cannot be used for
primary fire initiation inputs or notification outputs) such as access control, burglar, CCTV, intercom, voice, or other 3rd party systems. 32 I/O boards per FireNET panel (512 channels of
input/output points)
FN-4127-IO Hochiki Addressable Fire Alarm 1.000 đ SoldOut
  • 16 Channel Input/Output Board

    FN-4127-IO
  • The FireNET FN-4127-IO is a 16 channel Input/Output board that provides powerful input/output expansion & addition to the FireNET system allowing up to thirty two I/O boards to be connected to each FireNET panel within the FireNET network. Every I/O board connected to any panel is available to the entire network, which allows for network wide input/output mapping. Typical uses include graphical LED map displays/annunciators, tabular LED zone display/ annunciators, input/output logic to & from the fire system for secondary use (I/O board points cannot be used for
    primary fire initiation inputs or notification outputs) such as access control, burglar, CCTV, intercom, voice, or other 3rd party systems. 32 I/O boards per FireNET panel (512 channels of
    input/output points)

  • Manufacturer: Hochiki
  • Origin: US
  • Download:
    93.88 KB
- 16 channels of input/output points
- 32 I/O boards per FireNET panel (512 channels of input/output points)
- Each channel configurable as input or output point
- Inputs are opto-isolated non-supervised pulldown type triggered by “dry” contact from input source
- Outputs are open collector transistor pulldown type (100mA max each) that provide “wet” voltage output
- Simple 4 wire connection to control panel (2 for power, 2 for data)
- All inputs/outputs can be assigned to global functions, any event category, and used in network wide Cause & Effect logic
- Can be mounted locally within control panel enclosure or remotely via FN-ACC accessory enclosure up to 4000ft from the panel
- Each I/O board has a unique address 1-32 (set via DIP switch) on the I/O Comms Bus
- Input/Outputs are for secondary use, not for primary fire initiation inputs or notification outputs
- Two LED’s are provided for communication status


>>> Learn more: Hochiki Addressable Fire Alarm
>>> Learn more: Hochiki Conventional Fire Alarm
>>> Learn more: Other Product