Products - Viking FM-200 Fire Suppression System https://anphat.com/en/products/viking-fm-200-fire-suppression-system.html vi Fri, 5 Apr 2019 08:04:38 GMT Fri, 5 Apr 2019 08:04:38 GMT https://anphat.com/en/rss.html https://anphat.com/uploads/logo_7ecc26aa0884bc403d6dd32336df07cd.png Products - Viking FM-200 Fire Suppression System https://anphat.com/en/products/viking-fm-200-fire-suppression-system.html 144 25 FM 200 Clean Agent Cylinders (seamless) https://anphat.com/en/products/viking-fm-200-fire-suppression-system/fm-200-clean-agent-cylinders-seamless-8884XX-63-65-82-84-8885XX-74-76.html Fri, 5 Apr 2019 08:04:38 GMT The Fire Products FM 200 Fire Extinguishing System uses HFC-227ea extinguishing agent that is stored in the system’s extinguishing agent container(s) until system activation. The container assembly includes a seamless cylinder filled with HFC-227ea fluid ]]> FM 200 Clean Agent Cylinders (welded) https://anphat.com/en/products/viking-fm-200-fire-suppression-system/fm-200-clean-agent-cylinders-welded-889XXX.html Fri, 5 Apr 2019 08:04:55 GMT The Fire Products FM 200 Fire Extinguishing System uses HFC-227ea extinguishing agent that is stored in the system’s extinguishing agent container(s) until system activation. The container assembly includes a welded cylinder filled with HFC-227ea fluid]]> Pressure gauge https://anphat.com/en/products/viking-fm-200-fire-suppression-system/pressure-gauge-91210X.html Fri, 5 Apr 2019 07:04:23 GMT Monitoring device Halocarbon agents]]> Contact pressure gauge https://anphat.com/en/products/viking-fm-200-fire-suppression-system/contact-pressure-gauge.html Mon, 18 Mar 2019 08:03:44 GMT At nominal pressure the contact is opened. Contact makes with falling pressure or anticlockwise pointer motion
 ]]>
Selector valve BV https://anphat.com/en/products/viking-fm-200-fire-suppression-system/selector-valve-bv.html Mon, 18 Mar 2019 07:03:14 GMT The selector  valve  BV DN 25/40/50  is used in accordance with the "documentation   of special  extinguishing systems"   in fixed  C02,   argon,  nitrogen,   IG-55 and IG-541  high pressure  fire extinguishing   systems  or VSN  1230/200  fire systems  respectively.
In case of fire the selector valve DN 25/40/50 is used for flooding  selected  extinguishing   zones.
]]>
Safety device malfunction pressure SFD DN4 https://anphat.com/en/products/viking-fm-200-fire-suppression-system/safety-device-malfunction-pressure-sfd-dn4.html Mon, 18 Mar 2019 07:03:47 GMT The safety device malfunction pressure is used in accordance with the project-specific system schema in fixed fire extinguishing systems. The safety device malfunction pressure
is intended only for releasing small amounts of leakage in
pneumatic pilot lines. The safety device closes automatically on higher pressure.
]]>
Release device pneumatic https://anphat.com/en/products/viking-fm-200-fire-suppression-system/release-device-pneumatic.html Mon, 18 Mar 2019 07:03:18 GMT Pneumatic actuation of extinguishing  agent cylinder valves of type
80481/80482 (P21.231.131) and type 80480 (P21.211.131). One extinguishing agent cylinder valve each can be openend pneumatically.
]]>
Release device manual https://anphat.com/en/products/viking-fm-200-fire-suppression-system/release-device-manual.html Mon, 18 Mar 2019 07:03:46 GMT Manual actuation of extinguishing   agent cylinder  valves  of type
80481 (P21.231.131)   and type 80482 (P21.231.131).
One extinguishing   agent cylinder valve each can be openend manual.
]]>
Release device electrical https://anphat.com/en/products/viking-fm-200-fire-suppression-system/release-device-electrical.html Mon, 18 Mar 2019 07:03:02 GMT Electrical actuation  of extinguishing  agent cylinder valves of type
80481/80482 (P21.231.131) and type 80480 (P21.211.131). One extinguishing agent cylinder valve each can be open end electrically by applying of the nominal voltage.
]]>
Pilot control manifold C02 - DN15 https://anphat.com/en/products/viking-fm-200-fire-suppression-system/pilot-control-manifold-c02-dn15.html Mon, 18 Mar 2019 07:03:19 GMT The pilot control manifold DN 15 may only be used in accordance with system approval in stationary C02, argon, nitrogen, IG-55, IG-541 and VSN 1230/200 fire extinguishing systems. It is used as a pilot control  valve  in the pneumatic activation of fire extinguishing   systems  or as a C02   extinguishing agent  manifold  for small  design  quantity, for example local protection  for electrical  devices.]]> Pneumatic release device PAE - C02 electrical with protective cover https://anphat.com/en/products/viking-fm-200-fire-suppression-system/pneumatic-release-device-pae-c02-electrical-with-protective-cover.html Mon, 18 Mar 2019 07:03:45 GMT The release device PAE electrical  must only be used in accor• dance with system  approval  in stationary  carbon dioxide, argon, nitrogen, VSN 200  and VSN  1230 fire extinguishing systems. The release device PAE provides all pneumatic system parts with  carbon dioxide   (C02) as work  medium and is used to activate:
- Cylinder  batteries
- Selector valves
- Pneumatic control elements and alarm components (makrofon)
- Pneumatic door closing  devices
- Pneumatic pressure relief dampers.
]]>
Nozzles type CD https://anphat.com/en/products/viking-fm-200-fire-suppression-system/nozzles-type-cd.html Mon, 18 Mar 2019 07:03:32 GMT The nozzles CD are used as room protection nozzles in accordance with system  approval  in VSN 200 fire extinguishing systems using the extinguishing   agent HFC-227ea (Heptafluor propane ). They are used to supply the extinguishing agent within the calculated flow time and distribute it evenly throughout the extinguishing area.
 ]]>
Release device EM https://anphat.com/en/products/viking-fm-200-fire-suppression-system/release-device-em.html Mon, 18 Mar 2019 07:03:49 GMT The release device EM may be used only in accordance   with the "documentation    of special extinguishing   systems"  in fixed C02,   argon,  nitrogen,  IG-55 and IG-541fire  extinguishing systems.  It is used for electrical release of lever valve.
 ]]>
Monitoring loss pneumatic activation device PAE https://anphat.com/en/products/viking-fm-200-fire-suppression-system/monitoring-loss-pneumatic-activation-device-pae.html Mon, 18 Mar 2019 07:03:28 GMT The monitoring loss pneumatic activation device may only be used in accordance   with system approval in stationary C02-, argon-and nitrogen fire extinguishing systems. It facilitates monitoring of the permissible loss (5% - 10% supply per control cylinder). If the permissible margin of loss is exceeded the beam weight falls and actuates a reed contact limit switch.
The limit switch sends a fault message to the monitoring control panel and the fault is indicated locally via LED.
]]>
Limit switch ZS 256-11z https://anphat.com/en/products/viking-fm-200-fire-suppression-system/limit-switch-zs-256-11z.html Mon, 18 Mar 2019 07:03:54 GMT Pneumatic  timer  PV-3-BND,
Control device pneum.  SEP-2 and SEP-2-B.
]]>
Hose DN40 & DN50 https://anphat.com/en/products/viking-fm-200-fire-suppression-system/hose-dn40-dn50.html Mon, 18 Mar 2019 07:03:24 GMT To connect the valve of the extinguishing agent cylinder to the nozzle  pipe, the manifold, or the check  valve.]]> Check valve DN50 https://anphat.com/en/products/viking-fm-200-fire-suppression-system/check-valve-dn50.html Mon, 18 Mar 2019 06:03:10 GMT When using more than one cylinder at a conjointly pipework a check valve is to be used with each cylinder between cylinder and pipework or manifold.
This prevents that extinguishant gets to not operated valves or escapes unaimed with dismounted cylinders.

 ]]>
Hose DN40 https://anphat.com/en/products/viking-fm-200-fire-suppression-system/hose-dn40.html Mon, 18 Mar 2019 06:03:31 GMT To connect:
- The master  extinguishing   agent  cylinder  and the
pneum.  release  devices  of other extinguishing   agent  cylinder
- Two pneumatical release  devices
- The pneumatical release device and the pilot pipe of multi zone systems

 ]]>
Rigid Connection https://anphat.com/en/products/viking-fm-200-fire-suppression-system/rigid-connection.html Mon, 18 Mar 2019 06:03:30 GMT Rigid connection between the valve of the extinguishing agent cylinder and the downstream piping.
 ]]>
Adapter M12x1,5-G1/8 VSN 1230/200 https://anphat.com/en/products/viking-fm-200-fire-suppression-system/adapter-m12x1-5-g1-8-vsn-1230-200.html Mon, 18 Mar 2019 06:03:19 GMT To the connection of the hose DN4/pilot pipe with:
- Valves type  80481 , valves  type  80482
- Valves type  80480, BAS
- Release device  VSN  1230/200 pneumatic/manual
- Release device  VSN  1230/200 pneumatic
 ]]>
The manifold selector valve BV DN65/80/100 https://anphat.com/en/products/viking-fm-200-fire-suppression-system/the-manifold-selector-valve-bv-dn65-80-100.html Mon, 18 Mar 2019 06:03:25 GMT The manifold selector valve  BV DN65/80/100 pneumatic is used in accordance with "documentation of special extinguishing systems" in:
- fixed C02- high pressure fire extinguishing systems - argon-,  nitrogen, IG-55-, IG-541 extinguishing systems with Constant Flow (CF)
]]>
The Shuttle Noreturn Valve https://anphat.com/en/products/viking-fm-200-fire-suppression-system/the-shuttle-noreturn-valve.html Mon, 18 Mar 2019 06:03:11 GMT The shuttle  non-return  valve  is used  in fixed  high pressure C02,   argon,   nitrogen,  IG-55 and IG-541  fire extinguishing systems  or in VSN  1230/200  fire extinguishing   systems according  the system  approval.
 ]]>
Limit Switch Pneum Operated https://anphat.com/en/products/viking-fm-200-fire-suppression-system/limit-switch-pneum-operated.html Mon, 18 Mar 2019 06:03:44 GMT The  limit  switch  pneum. operated   may only  be used  in accor* dance  with system  approval  in stationary C02,    argon  and nitrogen  fire extinguishing   systems.]]>