Analog Addressable Fire Control Panel FireNET™6127/8127 Analog Addressable Fire Control Panel FireNET™6127/8127 The FireNET™ 6127/8127 control panel is an analog addressable fire alarm panel containing 6/ 8 SLC loops with each loop supporting 127 devices of any combination (sensors or modules), and 127 analog sounder bases, for a possible total of 254 points. Communication between devices is transferred through standard cable (shielded or twisted pair is not required).
The Loop Explorer Windows® Software interface provides the installer with fingertip access to installation programming and diagnostic tools. An Auto Learn feature offers the convenience
for quick start applications. FN-6127, FN-8127 is suitable for medium and large projects such as factories, apartments ...
FN-6127, FN-8127 Hochiki Addressable Fire Alarm 1.000 đ SoldOut
  • Analog Addressable Fire Control Panel FireNET™6127/8127

    FN-6127, FN-8127
  • The FireNET™ 6127/8127 control panel is an analog addressable fire alarm panel containing 6/ 8 SLC loops with each loop supporting 127 devices of any combination (sensors or modules), and 127 analog sounder bases, for a possible total of 254 points. Communication between devices is transferred through standard cable (shielded or twisted pair is not required).
    The Loop Explorer Windows® Software interface provides the installer with fingertip access to installation programming and diagnostic tools. An Auto Learn feature offers the convenience
    for quick start applications. FN-6127, FN-8127 is suitable for medium and large projects such as factories, apartments ...

  • Manufacturer: Hochiki
  • Origin: UK
  • Download:
    225.40 KB
- Analog design using Hochiki’s advanced DCP protocol for fast and robust communication
- Up to 127 sensors & modules, plus 127 analog sounder bases, for a total of 254 points possible per loop
- Uses standard wire, no shielded or twisted pair required on SLC loops
- Supports Class B (style 4) and Class A (style 6 or 7) SLC loops
- 8 on board Class B (style Y) NAC circuits rated at 2.5 Amp each
- Programmable sensitivity levels per device & automatic day/night sensitivity modes
- Automatic daily calibration & drift compensation routine
- Large 8-line x 40-character LCD display (320 char.)
- 6 or 8 loop version
- Dual RS-485 bus for panel network
- 2 built-in RS-232 interfaces for programming via a PC and two serial printer interfaces
- 10 on board programmable Form C relays rated at 1 amp at 30VDC (Fire1, Fire2, trouble, supervisory, aux.) x 2
- 1000mA of auxiliary power available rated at 24 VDC
- Loop Explorer Windows® configuration utility
- *500 network wide software zones
- Network Capability of up to 64 panels
- Two RS485 slave bus for expansion - up to 64 FN-4127- IO boards or up to 35 FN-LCD-S serial annunciators and/or up to 32 FN-4127-IO boards per bus
- Auto-learn feature
- Built in help and alarm information screens
- Fire Drill test function
- Walk Test function
- Alarm Verification feature
- Operates on 120VAC or 240VAC input voltage
- Powerful & versatile Cause & Effect programming (up to 500 maximum, network wide) including:
+ Cause & Effect action
+ Disable function configuration
+ Test mode configuration


>>> Learn more: Hochiki Addressable Fire Alarm
>>> Learn more: Hochiki Conventional Fire Alarm
>>> Learn more: Other Product